热门站点| 世界资料网 | 专利资料网 | 世界资料网论坛
收藏本站| 设为首页| 首页

SAE ARP1156 1992 Requisites for Design Specifications for Adsorptive Systems (Cancelled Dec 1969)

作者:标准资料网 时间:2024-05-10 08:49:15  浏览:8094   来源:标准资料网
下载地址: 点击此处下载
Product Code:SAE ARP1156
Title:1992 Requisites for Design Specifications for Adsorptive Systems (Cancelled Dec 1969)
Issuing Committee:
Scope:
下载地址: 点击此处下载
基本信息
标准名称:卡套式过板弯通管接头
英文名称:24° cone connectors - Bulkhead union elbow
中标分类: 机械 >> 通用零部件 >> 管路附件
ICS分类: 机械系统和通用件 >> 紧固件 >> 环、套管、管接头、承插
替代情况:替代GB/T 3749.1-1983;GB/T 3749.2-1983
发布部门:中华人民共和国国家质量监督检验检疫总局 中国国家标准化管理委员会
发布日期:2008-05-07
实施日期:2008-11-01
首发日期:1983-06-17
作废日期:
主管部门:中国机械工业联合会
提出单位:中国机械工业联合会
归口单位:全国管路附件标准化技术委员会
起草单位:中机生产力促进中心、建湖县特佳液压管件有限公司等
起草人:李维荣、左学俊、耿志学、徐长祥、周舜华、冯峰、陶忠明、阮浩丰、周剑飞、王利民
出版社:中国标准出版社
出版日期:2008-11-01
页数:8页
计划单号:20060772-T-604
适用范围

本标准规定了卡套式过板弯通管接头和接头体的尺寸、标记及技术要求。本标准适用于管子外径为6mm~42mm,最大工作压力10MPa~63MPa的液压流体传动和一般用途的管路系统。

前言

没有内容

目录

没有内容

引用标准

下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版均不适用于本标准,然而鼓励根据本标准达成协议的各方研究是否可使用这些文件的最新版本。凡是不注日期的引用文件,其最新版本适用于本标准。 GB/T 3759-2008 卡套式管接头用连接螺母
GB/T 3763-2008 管接头用六角薄螺母
GB/T 3764-2008 卡套
GB/T 3765-2008 卡套式管接头技术条件

所属分类: 机械 通用零部件 管路附件 机械系统和通用件 紧固件 环 套管 管接头 承插
Product Code:SAE J356
Title:Welded Flash-Controlled Low-Carbon Steel Tubing Normalized for Bending, Double Flaring, and Beading *HS-150/2000*
Issuing Committee:Metallic Tubing Committee
Scope: The SAE Standard covers normalized electric-resistance welded flash-controlled single-wall, low-carbon steel pressure tubing intended for use as pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, beading, forming, and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead.This specification also covers SAE J356 Type-A tubing. The mechanical properties and performance requirements of standard SAE J356 and SAE J356 Type-A are the same. Therefore, the designated differences of Type-A tubing are not meant to imply that Type-A tubing is in anyway inferior to standard SAE J356. The Type-A designation is only meant to address the unique manufacturing differences of the small diameter, light wall sizes (typically 15.88 mm OD x 1.24 mm wall and smaller.) The primary differences between SAE J356 and SAE J356 Type-A are described in the following paragraph.Type-A tubing is heat treated in-line to relieve stresses and is generally produced in coiled form. When Type-A tubing is produced in coil form, straight lengths of Type-A are only available through a secondary straightening and cut-to-length operation. Standard SAE J356 is produced as straight lengths and then receives a secondary normalizing operation. All standard SAE J356 requirements apply to Type-A tubing unless the specific requirement is noted with a 脪Type-A脫 designation. Standard SAE J356 is also available in the same sizes as Type-A, in which case all the standard SAE J356 specifications apply.
Rationale: The SAE Standard covers normalized electric-resistance welded flash-controlled single-wall, low-carbon steel pressure tubing intended for use as pressure lines and in other applications requiring tubing of a quality suitable for bending, double flaring, beading, forming, and brazing. Material produced to this specification is not intended to be used for single flare applications due to the potential leak path that would be caused by the ID weld bead.This specification also covers SAE J356 Type-A tubing. The mechanical properties and performance requirements of standard SAE J356 and SAE J356 Type-A are the same. Therefore, the designated differences of Type-A tubing are not meant to imply that Type-A tubing is in anyway inferior to standard SAE J356. The Type-A designation is only meant to address the unique manufacturing differences of the small diameter, light wall sizes (typically 15.88 mm OD x 1.24 mm wall and smaller.) The primary differences between SAE J356 and SAE J356 Type-A are described in the following paragraph.Type-A tubing is heat treated in-line to relieve stresses and is generally produced in coiled form. When Type-A tubing is produced in coil form, straight lengths of Type-A are only available through a secondary straightening and cut-to-length operation. Standard SAE J356 is produced as straight lengths and then receives a secondary normalizing operation. All standard SAE J356 requirements apply to Type-A tubing unless the specific requirement is noted with a 脪Type-A脫 designation. Standard SAE J356 is also available in the same sizes as Type-A, in which case all the standard SAE J356 specifications apply.

版权声明:所有资料均为作者提供或网友推荐收集整理而来,仅供爱好者学习和研究使用,版权归原作者所有。
如本站内容有侵犯您的合法权益,请和我们取得联系,我们将立即改正或删除。
京ICP备14017250号-1